C-120 Cement Underlayment and Patching Material
Product Description:
C-120 Cement is a specially formulated, fast setting, volume stable, calcium aluminate cement
based concrete and masonry patching material requiring only the addition of potable water for
mixing. C-120 Cement may be used interior or exterior, above or below grade on vertical,
horizontal and overhead surfaces without forms. After initial set, C-120 Cement may be shaved
to the contours of the surrounding area. C-120 Cement is used to repair and protect against
biogenic corrosion to manholes, wet wells, lift stations, concrete pipe, and waste water treatment
plants. C-120 has high resistance to sewage, extraordinary abrasion resistance and strong
resistance to biogenic corrosion by hydrogen sulfide (H2S) and sulfuric acid (H2SO4) found in
waste water environments. C-120 Cement incorporates proprietary fumed densifying agents enhancing
the product's ability to resist moist acidic conditions allowing for prolonged life of finished
surfaces. High alkalinity of C-120 mortars will provide good rust protection. Also, excellent
for the repair and protection of sidewalks, driveways, expressways, ceilings, walls, curbs and
panels. C-120 Cement may be used for applications under constant moisture contact.
Benefits:
- Rapid Setting
- Non-Shrink
- No Added Chlorides
- Shapeable
- Shaveable
- Use In Thin To Thick Layers
- Tenacious Bond
- Resistant To Freeze Thaw
- Light Color
Composition: Cement and selected aggregates.
Setting Time: ASTM C-403 |
|
| Initial Set: |
12 minutes |
| Final Set: |
18 minutes |
| Yield Per 45# |
.44 cubic feet |
| |
Compressive Strength: ASTM C-109 |
Split Tensile ASTM C-403 |
Shear Bond ATSM C-882 |
| 1 DAY |
5730 psi |
|
|
| 3 DAYS |
5950 psi |
|
|
| 7 DAYS |
6150 psi |
424 psi |
4210 psi |
| 28 DAYS |
7270 psi |
674 psi |
6530 psi |
| Freeze-Thaw Durability Factor: ASTM C-666 @ 300 Cycles: |
97.92 |
Directions For Use:
All areas to be patched shall be clean and free of oil, grease, dirt, deteriorated
concrete and all contaminates. Undercut the edges of the area to be patched to
accommodate the repair. C-120 Cement used to repair vehicular traffic bearing areas
should be placed a minimum of 1.5" in depth. Clean and prime any exposed steel and
reinforcing. Abrade or acid etch slick surfaces to ensure proper bond. When the
temperature is above 40O F, pre-wet the prepared area with potable water before applying
C-120. Any excess water should be blown or swept away to prevent dilution of the material.
C-120 Cement will require 3.25 to 3.5 quarts of potable water per 50 pound bag to
achieve the proper mix consistency. Add the measured amount of C-120 to the proper
amount of clean water and mix to a stiff putty like consistency for no more than four
minutes. Mix small quantities of C-120 in a clean container with a hand trowel or in a
wheelbarrow with a mud hoe. Use a rotary mixer with rubber tip blades for mixing larger
quantities, up to 90 lbs. In deep areas over 2", C-120 may be extended with up to 25 pounds
of clean, washed gravel per 50 pound bag for filler. Do not mix more material than can be
placed in five minutes. Do not re-temper with additional water.
Place C-120 Cement immediately after mixing. Force C-120 firmly into the area to be
patched by hand or with a trowel and mold to the desired shape. Compact thoroughly to
ensure bond. After initial set, finish C-120 with a steel trowel until smooth and level
with the surrounding surface. Do not overwork the material. Cure C-120 Cement with damp
cure method if any surface treatment will be used. Curing is mandatory especially in hot
weather, direct sunlight and for thin patches.
Cautions:
Mix C-120 no more than four minutes. Do not mix more material than can be placed in five
minutes. Use only potable water for mixing. Do not over water. Excess water does not
improve workability. Do not re-temper. Clean mixing equipment between batches. Do not
apply to frozen or frost filled surfaces. Do not apply during freezing weather. Contains
cement, avoid inhalation of dust. Wear gloves during the mixing and placement of material.
Packaging:
Fifty (50) pound (22.7 kg.) multiwall bleached paper bags. Fifty bags per pallet (2,500 pounds
per pallet)
Storage: 40O to 90 O F
Shelf Life:
1 year in original unopened package properly stored. Store in a dry location. Do not lay
bags directly on cement surfaces.
Freight Class: Class 50
Limited Warranty:
This product is warranted to be of merchantable quality when used according to the
instructions herein. It is not warranted to be suitable for any purpose or use other than
the general purpose for which it is intended. Liability under this warranty is limited to
the replacement of the product as purchased, if found to be defective upon inspection by the
manufacturer. This limited warranty is issued and accepted in lieu of all other expressed
warranties and explicitly excludes liability for consequential damages. Buyer assumes all
risk and liability resulting from the use of this product.
|